Megatherm starts Rs 70.05 crore higher-rated transformer expansion
Key highlights
- Megatherm has started construction on a Rs 70.05 crore transformer expansion, including working capital.
- Phase 2 is planned to add cast-resin transformers up to 12 MVA and power transformers rated at 220 kV and above.
- Shed 2 will cover 6,300 square metres with crane handling capacity up to 63 metric tonnes.
- H1FY27 total income rose 20.10% to Rs 196.49 crore, while reported profit after tax fell 20.83% to Rs 9.53 crore.
powered by IRIS

Megatherm has started construction on a Rs 70.05 crore, two-phase transformer expansion that is planned to add cast-resin dry-type transformers up to 12 megavolt-amperes (MVA) and power transformers rated at 220 kilovolts (kV) and above. The project includes a 6,300 square metre integrated shed on company-owned land and planned in-house transformer production processes.
Know Megatherm Induction inside out
Results, valuation, peers and who's buying, in one view.
What does Megatherm's Rs 70.05 crore expansion include?
Megatherm's expansion has a total project cost of Rs 70.05 crore, including working capital, with Rs 39.75 crore allocated to Phase 1 and Rs 30.30 crore to Phase 2. The presentation says construction has started on the proposed project, which includes a new shed, transformer product lines, induction equipment facilities, staff quarters, an experience centre and space for future expansion.
The new facility is a 6,300 square metre, single integrated pre-engineered Shed 2 on company-owned land. The site plan identifies areas for transformer backward integration, heavy-duty transformers, induction equipment and cast-resin transformers up to 12 MVA, alongside the existing facility.
Which transformer ratings will Megatherm add in each phase?
Megatherm plans to make cast-resin dry-type transformers above 2.5 MVA and up to 5 MVA in Phase 1, before extending the maximum rating to 12 MVA in Phase 2. Phase 2 also includes power transformers rated at 220 kV and above, while the presentation does not give a commissioning date for either phase.
Phase 1 covers induction-furnace, ladle-refining-furnace and arc-furnace transformers in small and large sizes. It also includes solar and storage inverter-duty transformers, industrial substation transformers, and smaller transformers typically rated between 2 MVA and 7 MVA for Megatherm's sintering systems, billet heaters, auxiliary applications and furnace duty.
Megatherm says cast-resin transformers use epoxy-encapsulated windings rather than oil and are suitable for indoor installations, data centres, wind turbines, metro projects and airports. Management's stated entry point above 2.5 MVA aligns with the Phase 1 ceiling of 5 MVA, while Phase 2 is intended to move the product range to 12 MVA.
How will Shed 2 support Megatherm's transformer plan?
Megatherm says Shed 2 will have heavy electrically operated travelling cranes with handling capacity up to 63 metric tonnes and clear height up to 12.5 metres. Those specifications are included with the planned heavy-duty transformer shed and the Phase 2 programme for 220 kV-and-above power transformers.
The planned core capabilities are winding, core and coil assembly, tanking and oil filling, vacuum drying and testing. Megatherm also plans Central Power Research Institute type testing for the new ratings in both phases, so approvals for those ratings remain a planned activity rather than a completed milestone.
The site layout reserves space for future expansion in addition to the 6,300 square metre initial shed. The defined distinction between phases is that Phase 1 establishes the shed and initial product lines, while Phase 2 raises the cast-resin rating limit from 5 MVA to 12 MVA and adds the 220 kV-and-above power-transformer programme.
Got a follow-up? Ask IRIS
Why is Megatherm bringing transformer processes in house?
Megatherm expects transformer backward integration to give it an edge, based on management's statement that backward integration in induction equipment has already benefited its induction-furnace business. The planned transformer processes include copper extrusion lines, tank fabrication, in-house machining of copper fittings and automatic insulation sizing machines.
These proposed processes sit alongside the production capabilities planned for Shed 2, including winding, coil assembly, tanking, oil filling, vacuum drying and testing. The presentation describes the transformer benefit as expected, unlike the induction-equipment example, meaning the outcome depends on executing the project and securing the planned type tests for new ratings.
Megatherm's stated transformer growth plan also includes renewable and industrial applications. It plans to expand beyond inverter-duty transformers into wind and hydro projects using approvals from more than 10 renewable-energy developers, while targeting steel, cement, ferro-alloy and chemical customers in domestic and export markets, with a focus on eastern India.
How does the expansion compare with Megatherm's H1FY27 performance?
Megatherm reported total income of Rs 196.49 crore in H1FY27, up 20.10% from Rs 163.61 crore in H1FY26 and 3.84% from Rs 189.23 crore in H2FY26. The Rs 70.05 crore project cost is therefore being undertaken during a half year in which income increased both year on year and sequentially.
Profit moved differently from income in H1FY27. Earnings before interest, tax, depreciation and amortisation were Rs 17.89 crore, down 11.14% from Rs 20.13 crore in H1FY26, and the margin declined to 9.10% from 12.30%; reported profit after tax fell 20.83% to Rs 9.53 crore from Rs 12.04 crore.
Megatherm's divisional presentation places transformers in a growth and investment phase alongside heating, hardening and foundry. Transformers carry an 18% overhead percentage, compared with 23% for heating, hardening and foundry, 11% for spares and services, and 10% for steel; these are overhead measures, not revenue or profit-margin shares.
Conclusion
Megatherm's Rs 70.05 crore project combines a wider transformer range with planned manufacturing integration. Phase 1 is intended to add cast-resin transformers above 2.5 MVA and up to 5 MVA alongside several furnace, industrial and inverter-duty lines, while Phase 2 targets cast-resin ratings up to 12 MVA and power transformers at 220 kV and above.
What to watch next is execution of the two phases and Central Power Research Institute type testing planned for the new ratings in both phases. Management has also disclosed plans to expand into wind, hydro and industrial transformer applications, supported by approvals from more than 10 renewable-energy developers, but it has not disclosed commissioning dates for the expansion.